TESTING

The wide range of analysis and quality testing services performed by our professional Testing team in Be.Do.Say are valued in the industries because we work hand to hand with our clients to verify the compliance with international standards and codes and we develop a consistent monitoring to identify potential risks.

SERVICE DETAILS

In Be.Do.Say we work with your success in mind offering a vast experience performing on-time assistance and in compliance with standards and codes. 

Be.Do.Say offers Mechanical Integrity Studies and Diagnosis, developed by our partners, to a wide range of mechanical equipment as carbon & stainless steel pressure vessels, fiberglass pressure vessels, atmospheric tanks, dixies, mixers,  boilers, glass reactors, carbon & stainless steel piping, among others, in order to verify remaining life calculation, corrosion rate and failure analysis, performing the following FAT (Factory Acceptance Test) and SAT (Site Acceptance Test):

Certified Engineers Level II-III by American Society For Non-Destructive Testing ASNT.

  • NDT´s  (VT, RT, PT, MT, UT) Non Destructive Testing in steel equipment, borosilicate 3.3 and fiberglass

Be.Do.Say performs FAT (Factory Acceptance Test) and SAT (Site Acceptance Test) to the following electrical equipment:

  • MV Metal Clad  & Metal Enclosed Switchers
  • LV Motor Control Center
  • Substations
  • Power & Distribution Transformers
  • Generators
  • Motors
  • HV Switches
  • Control & Protection Panel
  • Protection Revelators
  • Capacitor Banks
  • Chargers & Batteries Banks
  • Power Cables
  • Contactors

Listed below, enunciative but no limitative, are some of the Test Be.Do.Say performs:

  • Relay Test (Omicron)
  • Current Injection Test 2kV, 2000A (Omicron)
  • Hipot 200 kV, 5mA
  • Hipot 75kV, 5mA
  • Contact Resistance Test 10 kV (Ducter)
  • Simultaneity Test to Contacts, Switchers and Power Contacts
  • Power Quality Test (SEL)
  • Insulation Resistance Test 10 kV (Megger)
  • Current Injection Test (Masterpact Merlin Gerin, Schneider)
  • Current Injection Test (Magnum Switchers, Cutler Hammer-Eaton)
  • Current Injection 240A
  • Transformation Relation Test AEMC
  • Ground Resistance Test (Megger)
  • Electric Arc Resistance Suit
  • Temperature Measure (Thermograpic Camera)
  • Light Intensity Measurement (Lux Meter)
  • Circuit Tracker
  • Infrared Thermometer
  • Phase Sequence
  • Multimeters (Fluke)
  • Amp Meter (Fluke)
  • Voltage Detector (MV LV)
  • Torque Meter

Be.Do.Say performs FAT (Factory Acceptance Test) and SAT (Site Acceptance Test) on:

  • Operational & Functional Test
  • Continuity Test
error: